ColorManager::Init() (run by every Project construction) dereferenced
GetDefaultConfig() unconditionally. Any Project created before
SetUpDefaultConfig() crashed inside OCIO getCanonicalName on a null
config — the Windows CI SEGFAULT, where the suite order runs a
Project-creating test first. Reproduced locally by running
MainWindowLayoutInfo.AccessorsStoreAndRetrieve as the first suite.